Central and decentralised units for education

For 40 years, Orcon BV has been developing and manufacturing ventilation systems for housing and commercial buildings, with a special focus on schools. The company, based in Veenendaal, offers a range of balanced ventilation systems for this market. “Balanced ventilation is the ideal solution for schools when it comes to creating a healthy learning environment.” Orcon’s plug-and-play balanced ventilation systems come as standard with heat and cooling recovery.
Maintenance is relatively straightforward with the quiet WTU systems
Orcon supplies both central and decentralised systems. Sander Bruis, Product Development Manager: “The central WTU system can be installed either above or below the roof and is ideal for ventilating multiple rooms at flow rates from 600 m³/h. Thanks to the latest EC motors and intelligent controls, the systems have very low energy consumption. They are highly compact and do not require a condensate drain, thanks to an efficient thermal wheel. The decentralised WTU, by contrast, is ideal when several smaller rooms need ventilating, at flow rates of up to 2,000 m³/h. These systems are easy to install above a suspended ceiling, and their automatic bypass provides added comfort in the rooms. The decentralised WTU is also available with double insulation for particularly quiet operation. The enthalpy version does not require a condensate drain.”

A decentralised WTU-EC unit in the suspended ceiling of a classroom.
Quiet operation
Considerable effort has gone into making the WTU systems quiet. Bruis: “We achieved this by using the new EBM-Papst EC motors with backward-curved impellers, mounted in an aerodynamic EPS interior and upstream of the heat exchanger. The heat exchanger therefore acts as a silencer. For an even quieter installation, it is also possible to order a version with a double-walled casing and mineral wool insulation. Of course, for a good overall installation, it is important to use sound attenuators between the unit and the grille and to size them correctly.”
Cooling
As well as noise, temperature is becoming an increasingly important consideration for buildings, including schools. Bruis: “For comfort on hot summer days, the first priority is to keep as much heat out as possible, for example with solar shading. Heat recovery can help the ventilation system keep the heat out for as long as possible. We also offer primary cooling systems. The best solution is a primary system for cooling and heating that works intelligently with a ventilation system connected to a Freeverter DX heat pump, which provides a degree of additional cooling and heating for the clean air. From this year, our WTU systems are factory-ready to connect to this Freeverter heat pump combination, so they can also be upgraded at a later stage with additional top-up cooling and heating.”
A solution for every space
A central system is often the obvious choice for new builds. Renovation projects, however, often call for decentralised solutions and bespoke design. Bruis: “In recent years, we have equipped a great many schools with our WTU systems, often as part of renovation projects. So far, we have always managed to provide a suitable solution, regardless of ceiling height. Our WTU units are highly compact, and the E&IE version does not require a condensate drain, so it can also be wall-mounted. We are also seeing more and more systems installed in plain sight, for example in a school corridor.”

The WTU-EC-E features an enthalpy heat exchanger, which keeps relative humidity at a comfortable level.
Service hatches
Maintenance is relatively straightforward with the WTU systems. Service hatches are fitted at various points on the units. Bruis: “This gives you easy access to the most important components without having to lower the unit below the suspended ceiling. In addition, all modules, such as filters and heat exchangers, can be split into sections smaller than
60 cm, so they can be removed through a 60 by 60 cm ceiling opening. The intelligent controller allows the system components to be connected over a UTP network, with operating and maintenance status available from a single central point.”
Affordable
Tight budgets can be an obstacle to creating a healthy learning environment when building or renovating schools. Bruis: “Our WTUs have been developed in part to comply with the Frisse Scholen Class B programme.
We have not only considered the requirements: our lean working methods and carefully planned development process also help us keep the systems at a competitive price. Orcon supplies highly reliable, intelligent systems and provides full service throughout the entire project. This ranges from advice at the outset and training to support our customers, through to assistance with installation, commissioning and maintenance.”
Een zakelijke vraag aan Orcon? Get in touch
Companies in this story
Keep following this
Get an email when a new story is published. No account needed.
- ThemeHealthy indoor air
- SubjectFrisse Scholen
- CompanyOrcon