Fresh air and cooling from a single air handling unit

Vortvent Komfovent Verso STANDARD RHP: compact en veelzijdig.
Vortvent Komfovent Verso STANDARD RHP: compact en veelzijdig.

There are several ways to provide schools with sufficient fresh air. Many suppliers offer centralised and decentralised ventilation systems with heat recovery, for example. These solutions meet the requirements of the Programma van Eisen Frisse Scholen 2015, the GPR Gebouw 4 concept and the Bouwbesluit. “However, a pleasant and healthy indoor climate depends on more than fresh air alone,” says Ton Kistemaker, owner and managing director of Vortvent, a specialist in air treatment, ventilation and climate control. “Air is only truly fresh when it is also supplied cool. That is exactly what our new Komfovent Verso-RHP air handling unit with an integrated DX heat pump delivers.”

In summer, cooled air is essential to achieve the required operating temperature inside school buildings. Air conditioning can meet this need. However, it is now well known that in many cases the air is recirculated, at least to a large extent. This is an undesirable situation, particularly given the current coronavirus situation. With the Komfovent Verso-RHP, equipped with an integrated DX heat pump, Papendrecht-based Vortvent offers a solution that intelligently combines fresh air and cooling. “With the right controls, these units also make maximum use of outdoor temperatures,” says Kistemaker. “As a result, they provide the required cooling and heating while supplying more than the required amount of fresh ventilation air.”

Vortvent Komfovent Verso PRO RHP: packed with features.

Cooling load is the key factor

Choosing this complete solution from Vortvent, available from 400 to over 30,000 m³/h, in both standard and pro versions and suitable for indoor installation, has implications for the entire system. “If you opt for this solution, it is the cooling load, not the ventilation flow rate, that determines the design,” explains Kistemaker. “When the cooling load is taken as the starting point, the required airflow is generally considerably higher than for ventilation alone. This means, for example, that larger duct systems are needed. It also brings a number of other installation challenges.” 

Een zakelijke vraag aan Vortvent? Get in touch

Companies in this story

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • ThemeHealthy indoor air
  • SubjectFrisse Scholen
  • CompanyVortvent
Share this article

Advertisement

Follow Installatie & Bouw Nederland

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.