Frisse Scholen

Unique ventilation solutions for every school

Vele oplossingen voor schoolventilatie.
Vele oplossingen voor schoolventilatie.

There is no one-size-fits-all solution for creating a healthy indoor climate in schools. Every school board, consultant and installer knows that. Improving climate control systems in schools always calls for a bespoke approach. For Inatherm of Waalwijk, that is no problem. The company specialises in ventilation and air handling, and is part of HC Groep, a group of companies all active in indoor climate technology. Inatherm’s range is so extensive that there is a solution for every need. It has recently also started supplying 100% leak-free systems with heat recovery wheels.

“That broad range is no exaggeration,” says Niels Vugts, Technology & Innovation Manager at Inatherm. “We have everything you need for ventilation, air handling, temperature and humidity control, and air distribution. For decentralised solutions in schools, we recently introduced the NEX-T School Generation ventilation unit with heat recovery. This compact unit produces just 33 dB(A) at 950 m3/h. The NEX-T SG is available in various configurations, so there is a solution for every space.”

More than 500 schools in 60 years

If a central ventilation system is chosen, Inatherm has the widest range in the Netherlands, claims Vugts. “We offer more than sixty different types and models of air handling units and heat recovery units. Installed in front of or above the ceiling, freestanding or flat on the roof, with a plate heat exchanger or heat recovery wheel, in any capacity and with any desired technology and air distribution method. Complete solutions for schools are our strongest suit. We have been active in this sector for sixty years and have more than five hundred schools on our reference list. These range from small nurseries and primary and secondary schools to universities of applied sciences and universities, both new-build and renovation projects. We combine this extensive experience with the use of A-brands only, collaboration with highly qualified partners and a product range in which we innovate continuously.”

Automatic Leakage Control.

Transfer of contaminated air

The latest in a long line of innovations is now available for new and existing ventilation systems with a heat recovery wheel: Automatic Leakage Control (ALC™). Vugts explains: “With heat recovery wheels, ALC™ ensures 0% transfer between extract air and supply air. When a ventilation system is properly specified and provides sufficient air changes, the air in the room is continuously refreshed. This removes odours, among other things, as well as contaminants such as CO2, VOCs, dust, particulate matter and viruses. However, with an air handling system that uses a heat recovery wheel, a small proportion of the contaminated extract air may leak and be carried back into the fresh supply air. Naturally, you want to prevent that. ALC™ is the answer.”

Patented solution

Automatic Leakage Control therefore delivers leak-free heat recovery and is a unique addition to Inatherm’s well-known VEX heat recovery units. Vugts explains: “It is a patented system that has been independently tested by the Danish Technical University. It uses pressure sensors to continuously measure the air pressure upstream of the heat recovery wheel in the extract air, as well as the air pressure on the building side of the supply air. A fully automatic control damper ensures that the pressure in the supply section is always higher than in the extract section. This automatically reduces the transfer of extract air to 0%, even when a system ventilates on demand and therefore does not have a fixed airflow rate. With this solution, we can now supply ventilation systems with heat recovery wheels, guaranteed not to transfer any (contaminated) extract air into the fresh supply air. Users can still benefit from the advantage heat recovery wheels have over cross-flow or counterflow heat exchangers: they transfer moisture as well as heat. In winter, ventilating extensively with plate heat exchangers can cause humidity levels to fall sharply, which can in turn lead to all kinds of complaints. This smart system is also highly suitable for other applications, such as offices, healthcare facilities and hospitality venues. We are proud to bring this innovation to the market.”      

Question about this story? Ask your question

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • ThemeHealthy indoor air
  • SubjectFrisse Scholen
Share this article

Advertisement

Follow Installatie & Bouw Nederland

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.