Fire Safety & Accessibility: Self-closing apartment entrance doors

Amendment to the 2021 Building Decree.
An important amendment to the 2012 Building Decree on fire safety is the requirement for apartment entrance doors opening onto a shared hall or corridor to close automatically in the event of a fire. Previously, this applied only to apartment entrance doors in gallery-access buildings, but the requirement now also applies to fire-resistant apartment entrance doors opening onto, for example, a corridor.
An open apartment entrance door allows smoke to spread quickly through the communal area and escape route in the event of a fire. It is therefore important for the apartment entrance door to close when fire and smoke develop.

Concept 1
Complete free-swing door closer set: TS 5000 EFS free-swing door closer with RSZ 7.
Available for door leaf, transom and concealed installation.
With fail-safe function (in accordance with EN2535).
Version: wireless
Optional: wireless ceiling-mounted smoke detector. No cable required between the smoke detector and the GEZE free-swing door closer.
Free-swing door closer: advice
When a standard door closer is fitted to an apartment entrance door, it can cause practical and physical difficulties in everyday use. In practice, this often leads to the standard door closer being disabled, creating a risk that the door will no longer close automatically in the event of a fire. For this reason, GEZE recommends fitting an apartment entrance door with a free-swing door closer controlled by a smoke alarm or smoke detector. The free-swing door closer does not impede normal use and is activated only in the event of a fire. GEZE free-swing door closers controlled by a smoke alarm or detector are available in several installation configurations, from surface-mounted to concealed, with either an integrated smoke detector or a separate smoke alarm.

Concept 2
Complete free-swing door closer set: TS 5000 EFS free-swing door closer & smoke alarm set. Available for door leaf, transom and concealed installation.
With fail-safe function (in accordance with EN2535).
Version: wired.
Only one cable required between the smoke alarm and the GEZE free-swing door closer.
230 V input, stabilised 24 V output.
Control with fail-safe function
GEZE offers a versatile range of control options for its free-swing door closers, including an integrated smoke detector, a standard mains-powered 230 V smoke alarm in a wired version, and a wireless smoke detector. All versions have a fail-safe function in accordance with NEN2535. The maintenance of free-swing door closers controlled by a smoke alarm or detector is covered by the duty of care under Article 2.6, and they must be inspected annually. GEZE offers several options for this.

Concept 3
Complete free-swing door closer set: TS 5000 RFS free-swing door closer with integrated smoke control unit. With fail-safe function (in accordance with EN2535).
Version: wired.
For door leaf and transom installation on the hinge side. Optional: wireless ceiling-mounted smoke detector. No cable required between the smoke detector and the GEZE free-swing door closer.
Certified solutions for every situation
GEZE has put together several concepts to provide a suitable, certified solution for apartment entrance doors in every situation, whether for new-build projects or upgrades to existing buildings. Speak to one of our GEZE advisers for guidance. They will be happy to support, inform and advise you on the most suitable solution for your project.

Read the GEZE brochure ‘Fire Safety & Accessibility’ for more information on this topic and the GEZE concepts.
For more information on free-swing door closers, the 2012 Building Decree, certificates, GEZE products or advice, visit: www.geze.nl.
Question about this story? Ask your question
Keep following this
Get an email when a new story is published. No account needed.
- ThemeSafe building services and buildings
- SubjectGeneral