General

Sustainable ventilation upgrade for Rijkskantoor Laan op Zuid

Sustainable ventilation upgrade for Rijkskantoor Laan op Zuid

On Laan op Zuid in Rotterdam, Heijmans is renovating the former Tax Office into a government office for five government services: the Belastingdienst, Douane, Rijkswaterstaat, Dienst Uitvoering Onderwijs and Raad voor de Kinderbescherming.

Commissioned by the Rijksvastgoedbedrijf and designed by OTH architecten, this remarkable feat of engineering is taking shape. The building’s plinth is being given a new entrance, which involved opening up the façade and removing several sections of floor. Two additional storeys have been added to the car park deck. Heijmans is also carrying out the phased refurbishment of the four towers. Work is currently under way on the final phase: tower D. The entire project is due for completion this summer.

Detail of the EC fans.

Systemair became involved in the renovation in January 2019 to upgrade the ventilation system. “We supplied air handling units for the Tax Office back in the early 1990s,” says account manager Sjef Verboven. “These were standard units with a filter, heater, cooler, fan and humidifier, as heat recovery was not yet a requirement. The ERP/Ecodesign Directive was also not yet in force. The air handling units supplied around 250,000 m³ of air per hour. The incoming outdoor air was heated to the required room temperature using district heating.” At an outdoor temperature of -10°C, as much as 2,500 kW of heating capacity was needed, he explains. “To reduce this energy consumption, heat recovery and a heat pump were desirable. For the heat recovery system, we worked with Heijmans on a design that also included cleaning and the necessary refurbishment of the air handling units. We started work on building section A in mid-2019.”

Multi-coil system

Heat recovery makes it possible to reduce the installed heating capacity by more than half, says Verboven. “This project uses a multi-coil system, in other words, a twin-coil system with two exhaust air cooling coils. The existing heaters and coolers have also been replaced by a single new changeover coil for the heat pump and future aquifer thermal energy storage (ATES) system. In the supply air units, fitting the changeover coil and modifying the damper section created space for the multi-coil heater.” The exhaust air units presented a greater challenge: “The casing had to accommodate a filter and multi-coil cooler alongside the fan. This was possible because, for energy-saving reasons, the existing fans in these units were replaced with an EC fan wall, which allows for a very compact installation. This meant the existing casing could be retained. Only the connections on the suction and discharge sides had to be enlarged to the full cross-section of the casing.”

Systemair thoroughly cleaned all the air handling units. The outdoor air intake, filter and silencer sections were completely stripped out, recoated where necessary and fitted with new components. This ensures optimum hygiene as well as energy-efficient air treatment.

A positive working relationship

As with any renovation, a number of unexpected issues arose during this project. “For example, the side walls and silencer splitters of the air handling unit in tower A had to be temporarily removed to make room for the heat pumps to be brought in,” says Verboven. “We worked with Heijmans to find an excellent solution. We would like to thank project manager Jan Smidt and the Heijmans team for the positive working relationship and their collaborative approach. Tower D is due for completion in a few weeks. We will then be able to look back on a very successful and sustainable renovation project. We have upgraded all our installations to the latest technical standards, making maximum use of existing materials and, apart from a few transition pieces, the existing ductwork.”  

A business enquiry for Systemair? Get in touch

Wie aan Toren op Zuid werkte

  1. clientREAL I.S. AGMentioned in Toren op Zuid | Rotterdam: ‘Building services fully exposed at Toren op Zuid in Rotterdam’
  2. construction managementSavillsMentioned in Toren op Zuid | Rotterdam: ‘Building services fully exposed at Toren op Zuid in Rotterdam’
  3. architectV8 architectsMentioned in Toren op Zuid | Rotterdam: ‘Building services fully exposed at Toren op Zuid in Rotterdam’
  4. structural engineerRoyal HaskoningDHVMentioned in Toren op Zuid | Rotterdam: ‘Building services fully exposed at Toren op Zuid in Rotterdam’
  5. building contractorDura VermeerMentioned in Toren op Zuid | Rotterdam: ‘Building services fully exposed at Toren op Zuid in Rotterdam’
  6. advies brandbeveiliging en akoestiekDGMRMentioned in Toren op Zuid | Rotterdam: ‘Building services fully exposed at Toren op Zuid in Rotterdam’
  7. advies installatiesDeernsMentioned in Toren op Zuid | Rotterdam: ‘Building services fully exposed at Toren op Zuid in Rotterdam’
  8. building servicesBosman BedrijvenMentioned in Toren op Zuid | Rotterdam: ‘Building services fully exposed at Toren op Zuid in Rotterdam’
  9. air handling unitsSystemairIn this story
  10. architectOTH architectenIn this story
  11. renovationHeijmansIn this story

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • ProjectToren op Zuid
  • ThemeHealthy indoor air
  • SubjectGeneral
  • CompanySystemair
  • CompanyOTH architecten
  • CompanyHeijmans
Share this article

Follow Installatie & Bouw Nederland

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.