The quietest attenuators in the Netherlands

Driven by high energy prices and climate targets, more and more homeowners are choosing to make their homes more sustainable. Cavity wall and roof insulation, along with triple glazing, prevent energy (heat) from escaping and create the perfect conditions for a heat pump. “Anyone who insulates thoroughly must also ensure adequate ventilation,” stresses Henry Kale, Account Manager at Panflex. “Fortunately, more and more residents are aware of this. Heat recovery ventilation systems are selling like hot cakes. This is a positive development, but unfortunately it brings a new problem: noise nuisance.”

“Our Building Decree stipulates a maximum installation noise level of 30 dB(A). Since an MVHR system produces an average of 55 to 60 dB(A), a significant amount of noise needs to be filtered out,” says Kale. “To prevent noise nuisance, it is important that the system is properly designed and installed. Not only must duct diameters, air volumes and air speeds be correct, but the system must also be free of obstructions. After all, resistance also creates noise. Attenuators on the unit and the valves can then provide additional attenuation.”
Quick and effective
Motors in MVHR systems produce low-frequency tones from 125 to 500 hertz, Kale explains. “These are ‘long waves’ that you want to remove from the airflow as quickly and effectively as possible. To achieve insertion loss, acoustic ventilation hoses or attenuators of at least 1 metre are required. Our products meet this specification exactly. In fact, we offer the best and quietest attenuators available on the market!”
Attenuated at source
The acoustically insulated, flexible ventilation hoses form part of Panflex’s MVHR Package, which also includes two thermally insulated ventilation hoses, eight stainless steel hose clamps and a roll of Alutape. “Our MVHR Package is available for all standard diameters (125 to 200 mm), consists exclusively of A-brand products and is stocked as standard by well-known technical wholesalers,” says Kale. “The acoustic ventilation hoses are already taped at one end, so they can be connected directly to the MVHR unit. This means as much noise as possible is attenuated at source. The use of itch-free Ecose insulation wool also ensures easier installation and the best possible sound attenuation. In the most common diameters, with a hose length of 1 metre, we can reduce noise by 30 to 33 dB(A)! That makes us unique in the Netherlands.” For those looking to reduce cross-talk as well as insertion noise, Panflex also offers an extensive range of cross-talk attenuators.
Question about this story? Ask your question
Keep following this
Get an email when a new story is published. No account needed.
- SubjectGeneral