ATEX-safe ventilation system for cheese factory
Text Lieke BousemaImage Systemair

Ventilating industrial applications often also involves extracting harmful and explosive gases. “Many industrial buildings still use synthetic refrigerants for cooling,” says Hans Honings, Account Manager, Industrial department at Systemair. “As these refrigerants have a greater impact on the greenhouse effect, the European Union’s F-gas regulations require the use of synthetic refrigerants to be reduced and, for example, replaced with ammonia (NH₃). This natural refrigerant has excellent thermodynamic properties, enabling ammonia-based refrigeration systems to achieve very high energy performance. However, ammonia is also toxic and flammable. Refrigerant leaks caused by, for example, dried-out hoses or cracked hose clamps must therefore be prevented from escalating. Strict safety protocols apply, including the use of ATEX fans in plant rooms.”
Systemair offers a comprehensive range of fans that can be configured in full compliance with the current ATmosphere EXplosible (ATEX) directive (2014/34/EU). The range includes roof fans, centrifugal fans and axial fans. “A key requirement for ATEX fans is that they must not cause sparks,” explains Honings. “Over time, a fan impeller can become slightly unbalanced, creating a risk that it will strike the casing. This can generate sparks which, in the event of an ammonia leak, could cause a major explosion or even a fire. By contrast, the motor, impeller and casing of an ATEX fan are designed so that sparking is impossible. The fans are connected to special sensors that measure the level of contamination in the room. Should refrigerant be released, the plant room is immediately and effectively extracted. This allows the fire brigade and other emergency services to enter the plant room safely, while minimising consequential damage to the building, people and the environment.”

Cheese factory
Systemair supplied three ATEX axial fans for a cheese factory, where the old refrigeration units using synthetic refrigerants had recently been replaced with an NH₃ system. “As there is an upper floor above the plant rooms, roof fans were not an option,” says Honings. “They would have required us to run ductwork through the upper floor. Our ATEX AW-EX axial wall fans provide a well-designed alternative in this case, allowing contaminated air to be extracted through the façade. They also provide standard room ventilation.” The low-pressure axial wall fans have an impeller diameter of 355 mm and can deliver around 2,000 m³/h of air exchange.

ATEX-safe ventilation system
As the plant rooms also adjoin other rooms, Systemair supplied three self-closing fire dampers with fusible links, ensuring a fully ATEX-safe ventilation system, says Honings. “In the event of a fire, the fire dampers close automatically and immediately, keeping the wall fire-resistant for one hour. This allows staff and others in the cheese factory to escape safely. Both the ATEX axial fans and the fire dampers were installed in the fire-resistant partition walls, working in partnership with a trusted installation contractor.”
A business enquiry for Systemair? Get in touch
Companies in this story
Keep following this
Get an email when a new story is published. No account needed.
- ThemeGas-free heating and cooling
- SubjectHVAC
- CompanySystemair