Simple installation, maximum control, high comfort
Text Lieke BousemaImage Ned Air

Central air handling units with space-saving ventilation units are proving a hit in small flats
Healthy indoor air, everywhere and at all times. This has been Ned Air’s ambition for more than 30 years, in offices, schools and apartment buildings alike, where shared facilities and smaller living spaces are increasingly the norm. “As flats get smaller, demand for smart, space-saving solutions is growing,” says Dennis Osinga, Area Manager at Ned Air. “We are successfully meeting this demand with our Everyline and Rotorline air handling units, combined with our space-saving SkyFlow ventilation system.” This smart system combination gives both installers and clients one point of contact, one supplier, one service partner and one warranty provider for the complete ventilation system. It can also be easily accessed, commissioned and monitored online and remotely.

Plenty of fresh air
SkyFlow is a compact, lightweight ventilation system with an adjustable damper section, designed to respond optimally to the conditions and needs of apartment buildings. “The ventilation system combines high comfort, good humidity control and precisely the right amount of clean, fresh air with easy maintenance and a compact design,” says Osinga. “At apartment level, installers and clients can choose between a 1-zone or 2-zone system. Each unit comprises two or three damper modules with flow measurement, ensuring that ventilation is always balanced in each flat. Adding temperature, CO2 and relative humidity sensors enables demand-controlled ventilation in each room. This means the system never ventilates more than necessary, helping to significantly reduce energy costs.”

Adjusting air volumes
SkyFlow’s damper modules connect to the central riser, which receives fresh air from the central air handling unit. This can be an air handling unit of various makes and types. “Choosing to pair the system with Ned Air’s Everyline or Rotorline brings significant synergies,” says Osinga. “For example, the control of the ventilation unit and air handling units is closely coordinated to refine the ramp-up and ramp-down process. Our air handling units incorporate a System Optimize Controller (SOC) control module, which communicates with each individual SkyFlow damper module. This makes it possible to adjust air volumes (air pressures), preventing unnecessary pressure in the duct.” The SOC control module also enables remote monitoring. “This allows us to provide customers with even better, more comprehensive service. We proactively monitor when servicing or maintenance may be needed. What’s more, issues can be identified and resolved before building occupants notice anything. This creates added value for occupants and installers, while further extending the service life of our systems.”

No maintenance inside individual flats
Apartment buildings today often contain 100 to 500 homes, says Osinga. “This means maintenance providers have to deal with hundreds of residents, with separate maintenance appointments generally needing to be arranged with each one. SkyFlow avoids this complex task. The system in the homes is essentially maintenance-free. For example, rather than placing the air filters in the damper modules themselves, we have located them in the central air handling unit. There is therefore no longer any need to replace filters inside individual flats.”
Compact design
Osinga concludes his extensive list of benefits with SkyFlow’s compact design and low weight. “Installers can fit the system easily, with the option of wall or ceiling mounting. This keeps the floor clear and allows residents to furnish their flat without obstruction.” The SkyFlow damper module has a connection diameter of 160 mm. “The system can renew more than 400 m3/h, which is more than enough for most flats. With no fan or filter, it operates silently.”
Minimum pressure, maximum energy savings
By far the majority of apartment buildings operate at a constant system pressure. The closer a damper is to closed, the less fresh air is needed in the flat. Nevertheless, some systems are set to maintain a minimum pressure, notes Osinga. “Instead, we open the damper slightly further while reducing the pressure. This keeps occupant comfort high while significantly reducing energy consumption. That is particularly valuable now that energy prices are rising and new, stricter energy rating requirements are on the horizon. This technology in particular, combined with the advanced control module in the air handling unit, makes SkyFlow an ideal solution for multi-storey housing.”
A business enquiry for Ned Air? Get in touch
Companies in this story
Keep following this
Get an email when a new story is published. No account needed.
- ThemeHealthy indoor air
- SubjectHVAC
- CompanyNed Air