HVAC

Sustainable heating solution with a ground-source heat pump and Radson radiators

Sustainable heating solution with a ground-source heat pump and Radson radiators

Albreco Aardwarmte Systemen, an installation company in Katwijk and expert in sustainable heating solutions, has installed a geothermal system combined with a heat pump in its own premises. To heat different business areas individually, Albreco has installed, among other products, Radson (BE) Ulow-E2 low-temperature radiators.

Radson (BE) Ulow-E2 low-temperature radiators provide individual heating and cooling for different business areas and can be easily used with any type of heat pump

Marcel Imthorn is managing director and owner of Albreco Aardwarmte Systemen, an installation company specialising in geothermal energy as a sustainable solution for heating and cooling buildings. At his own premises in Katwijk, Imthorn has connected the ground-source system to a heat pump. To heat several rooms individually, Radson Ulow-E2 radiators have been installed in Albreco’s premises. These radiators combine radiant heat with enhanced convective heat and operate at a low temperature that is warm enough to keep a room comfortable. “The office stays at 21oC, while heating costs have been significantly reduced.” Imthorn says geothermal energy is an interesting and effective technology for heating and cooling a building sustainably.

Over the past thirteen years, Albreco has installed 1500 ground-source systems in the Netherlands in all kinds of existing and new buildings. “The ground-source system uses existing sustainable energy stored in the earth’s core and warmed by the sun,” he explains. “This energy lets you heat and cool your building affordably and comfortably.” To access this energy source, a number of boreholes are drilled to an average depth of 100 to 200 metres. The number of boreholes depends on the amount of energy required by a building. “The temperature of the ground at a depth of 200 metres is always around 12oC on average. A heat pump is connected to this system and can run on geothermal energy at 0oC. The heat pump contains a compressor and refrigerant, which can raise the low ground temperature to 30 to 35oC for heating, or up to 60°C for domestic hot water. Combined with low-temperature radiators or underfloor heating, the heat pump provides low-temperature heating that can sustainably warm your home or office in winter and cool it in summer,” Imthorn explains.

“The ground-source system, which is at 12 oC, is also suitable for cooling a building sustainably in summer. It can keep the indoor temperature 4 degrees below the outside temperature. It also uses far less energy than air conditioning,” Imthorn notes. The initial installation cost of a ground-source system averages 20.000 euros, but annual energy costs fall by 40 to 70% compared with fossil fuels. In new-build projects, the system pays for itself within ten years; with renovation, it can take a little longer. This ground-source system is ideal for storing heat in the ground over an extended period. “Heat generated in the building in summer can be stored in the ground and used to heat the building again in winter,” says Imthorn.

For his 500-square-metre premises in Katwijk, Imthorn chose a combination of underfloor heating and the Ulow-E2, a low-temperature radiator that can be connected to any heat pump. The premises comprise several offices, a canteen, a workshop, a warehouse and changing rooms for outdoor staff, where wet workwear is hung up to dry. Jan-Willem Plukaard is sales manager for sustainable products at Radson in the Netherlands and was involved in installing the Ulow-E2 radiators at Albreco’s premises. “We installed two Radson Ulow-E2 radiators in the canteen and changing rooms, heating 100 square metres,” says Plukaard. Underfloor heating has been installed in the other areas, covering a total of 400 square metres of the office building. Both the underfloor heating and the Ulow-E2 radiators operate on the same low-temperature system. “Albreco chose the Ulow-E2 for the canteen and changing rooms because these spaces need to be brought up to a comfortable temperature quickly and efficiently in winter,” says Plukaard.
“Underfloor heating is too slow for these spaces. The advantage of the Ulow-E2 is that it can be connected to different heat generation systems, as these systems operate at the same low temperature of 35 oC. The same applies to underfloor heating,” Plukaard explains.

Imthorn sees Radson’s Ulow-E2 radiators as a good replacement for traditional radiators. “We’re very enthusiastic about the Ulow-E2. The radiators are easy to use on a plug & play basis, with a plug that goes into the socket and a control panel that is straightforward to operate. We found last winter that the changing rooms and canteen in our premises heat up quickly with the Ulow-E2. The Ulow-E2 is sustainable because it operates at low temperatures of up to 35 oC, which uses less energy. The radiators are also exceptionally easy to hang and install on existing heat generation systems. For the installer, there is no difference: the Ulow-E2 radiators are connected hydraulically, just like traditional radiators,” says Imthorn. The Ulow-E2 can be connected to any type of heat pump, and each radiator can be adjusted independently. The Ulow-E2 can also heat a room comfortably without underfloor heating. From an installation perspective, the Ulow-E2 system therefore requires no major investment, as it simply needs to be connected to the building’s heat emitter or heat generation system. According to Plukaard, it is an interesting development that other manufacturers of sustainable heat generation systems are now discovering this combination system, as Albreco has. “It’s good to see this manufacturer using the Ulow-E2 in its own office building, while already applying it to other projects too. That shows this sustainable heating system delivers the desired results in practice,” says Plukaard.

Question about this story? Ask your question

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • ThemeGas-free heating and cooling
  • SubjectHVAC
Share this article

Advertisement

Follow Installatie & Bouw Nederland

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.