Van der Valk Hotel, Zuidas | Advanced air handling for Van der Valk Hotel Amsterdam

The new Van der Valk Hotel on Amsterdam’s Zuidas is making use of as many innovative and sustainable technologies as possible, including for its air handling. WOLF Energiesystemen’s air handling units and post-treatment units play a major role in this. “All the air handling units for this project were designed to meet Eurovent label A or A+”, says Martin Wendels, director of WOLF Energiesystemen. “The air handling units are designed to operate at low water temperatures, ensuring optimum efficiency.”
Commissioned by installing contractor Linthorst Techniek, WOLF Energiesystemen is supplying and installing eight air handling units: five for the hotel floors, one for the restaurant, one for the communal areas from the ground floor to the 4th floor, and one for the conference and meeting rooms. The Kampen-based systems supplier is also jointly responsible for moving the equipment inside the building. “The air handling system for the restaurant area is particularly special”, says Wendels. “We have integrated Linthorst Techniek’s Kitchen Air Technologies (KAT) filtration system
into this system, which cleans the warm air from the kitchen and passes it through a cross-flow heat exchanger. The KAT system uses a specially developed liquid that is atomised in the kitchen system’s extract duct. The released grease vapours and odours bind to this liquid, after which they are captured by a special KAT filter. This makes it possible to sustainably reuse energy and heat that would normally be lost to the outside. It also minimises the impact on the surrounding area. The air handling unit for the restaurant has an airflow rate of almost 30,000 m³/h and is equipped with a high-efficiency plate heat exchanger. Continuously variable EC fans ensure minimum energy consumption.”

As space in the plant room in the car park was limited, we devoted considerable attention to the engineering and dimensions of our units.
On show
The air handling unit for the restaurant area is located in the car park beneath the hotel floors, alongside the air handling units for the communal areas and the conference and meeting rooms. “As space in the plant room in the car park was limited, we devoted considerable attention to the engineering and dimensions of our units”, says Wendels. “One nice detail is that the equipment will remain on show after handover.”
An air handling unit with an airflow rate of 16,000 m³/h provides optimum ventilation for the conference and meeting rooms. “This unit is equipped with a high-efficiency sorption heat wheel, which actively recovers heat and also maximises moisture recovery. Continuously variable EC fans ensure minimum energy consumption here too. For the communal areas, including the brasserie, an air handling unit with an airflow rate of 12,250 m³/h was selected. This unit also includes a KAT filtration system from Linthorst Techniek, combined with a high-efficiency plate heat exchanger.”
All the air handling units in the car park are connected to post-treatment units from WOLF Energiesystemen, which provide additional heating or cooling. The air handling units were supplied complete with field equipment, ensuring optimum efficiency on site.
Complete products
The air handling units for the hotel rooms will be installed on the roof of the Van der Valk Hotel. “These units have airflow rates ranging from 4,250 to 6,000 m³/h and are designed to meet Eurovent energy label A+. As the bathrooms are also connected to the systems, counterflow plate heat exchangers with efficiencies of up to > 90% were selected. The units are supplied complete with controls, using Modbus communication in this case, for straightforward integration into the building management system.”
A business enquiry for WOLF Energiesystemen? Get in touch
Wie aan Hotel Van der Valk Amsterdam werkte
- stekerbare installatie
IsolectraMentioned in Thoughtfully designed plug-in installation adds the finishing touch to Van der Valk Amsterdam - stekerbare oplossingenWielandMentioned in Thoughtfully designed plug-in installation adds the finishing touch to Van der Valk Amsterdam
- KNX componentenEelectronMentioned in Thoughtfully designed plug-in installation adds the finishing touch to Van der Valk Amsterdam
- hotelfamilieVan der ValkMentioned in Thoughtfully designed plug-in installation adds the finishing touch to Van der Valk Amsterdam
- installerLinthorst TechniekIn this story
- technische groothandelTechnische UnieMentioned in Van der Valk Hotel, Zuidas | A toucan touches down on Amsterdam’s Zuidas
- WINSTA®-systeem
WAGOMentioned in Van der Valk Hotel, Zuidas | Van der Valk Hotel Zuidas to get plug-in lighting installations - regie over het prefab procesGroothandel Technische UnieMentioned in Van der Valk Hotel, Zuidas | Van der Valk Hotel Zuidas to get plug-in lighting installations
Keep following this
Get an email when a new story is published. No account needed.
- ProjectHotel Van der Valk Amsterdam
- ThemeHealthy indoor air
- SubjectHVAC
- CompanyWOLF Energiesystemen
- CompanyLinthorst Techniek