Building services engineering

‘A listed farmhouse with a modern heating system’

‘A listed farmhouse with a modern heating system’

A 1740 longhouse farmhouse in Erp has been fitted with hydraulic balancing, air and dirt separation in one compact unit. Installing this SpiroCross enables Spirotech to connect a combined heating system with radiators and underfloor heating to an 8 kW Atlantic hybrid monobloc air-to-water heat pump and a boiler. A modern heating system in a historic farmhouse. 

‘Good hydraulic balance in an installation with separate circuits

The SpiroCross was installed in this typical Brabant listed farmhouse because the heat pump is some distance from the boiler. This is partly because the property is long and narrow, with long pipe runs. Additional pumps are therefore needed to circulate the water. The farmhouse’s residents chose a hybrid heat pump to save energy during the shoulder seasons and reduce gas consumption. “The heat pump heats the house when the outside temperature is above 4°C. Below 4°C, the boiler kicks in,” says the resident. “The farmhouse has been modernised inside, is well insulated and has balanced ventilation. Heat loss is therefore limited. Naturally, all of that needs to be in order before you install a heat pump; otherwise, there’s no point.” 

Three in one

Hydraulic balancing, air separation and dirt separation are important in a heating system. The SpiroCross combines all three functions in one unit. This saves not only on installation and maintenance costs, but also on the purchase price. The unit has four connections, far fewer than the eight required if a separate air and dirt separator and an open header were installed. The SpiroCross can be used in both new-build and renovation projects involving heating, cooling and process installations. The unit is particularly suitable for a small cascade or a combined system, as in the farmhouse, where the heat pump’s pump does not have enough capacity and the pressure loss over the long pipe runs is too high. 

Low pump head

“The heat pump’s pump does not have enough head to deliver sufficient water to the radiators because the pipe runs are long,” says the resident, who has a strong technical background. “The SpiroCross sits between the heat generators, the heat pump and boiler, and the heat emitters, the underfloor heating and radiators. To ensure proper water circulation, water flows from the heat pump to the SpiroCross, and from there to the underfloor heating and radiators. Pumps on both sides ensure proper circulation.”

The unit has four connections instead of the eight that would be needed if separate components were installed.

Constant low pressure drop

The SpiroCross is made of brass. It has two connections on one side for the boiler and heat pump, and two on the other for the radiators and underfloor heating. The SpiroCross can separate the primary and secondary circuits. “The pumps on either side therefore do not affect each other,” says the resident. “Hydraulic balancing, air separation and dirt separation are important in a heating system. Once the system is balanced, there is almost no mixing of return and supply water.” This means the temperature is maintained. “There are two separate circuits, which prevent the pumps from affecting one another,” the resident explains. “The SpiroCross keeps the pumps separate. The system has a circulation pump on each side to overcome resistance and ensure sufficient flow. The air separator is at the top and the dirt separator at the bottom, with a magnet clipped to the outside of the casing to capture magnetic dirt particles.”

The SpiroCross sits between the heat generators, the heat pump and boiler, and the heat emitters, the underfloor heating and radiators.

Spirotube

The SpiroCross contains a twisted tube, the Spirotube, with copper wires. These create a zone of still water at the top of the SpiroCross, allowing bubbles to rise and be discharged through a float and valve. A magnet clips easily around the casing to separate dirt effectively, capturing magnetic particles more quickly. The dirt is discharged through a tap at the bottom. This needs to be done from time to time.

Spirotech already supplied an air separator and a dirt separator. The SpiroCross combines the two. The company already had a SpiroCross without a magnet. The latest version adds a magnet to capture magnetic particles even more quickly. The SpiroCross has a compact design and a low installation height, thanks to the Spirotube.

Extensively tested

Spirotech developed the SpiroCross using Computational Fluid Dynamics. The unit has been extensively tested in various installations, both in the field and on the company’s own TÜV-certified test and measurement rig. 

A business enquiry for Spirotech? Get in touch

Companies in this story

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • ThemeGas-free heating and cooling
  • SubjectBuilding services engineering
  • CompanySpirotech
Share this article

Follow Installatie & Bouw Nederland

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.