A smart, pluggable installation for every home

Isolectra and Wieland’s pluggable installation systems offer a solution for every housing project, from large to small, traditional to prefabricated, and dry to wet finishing methods.
To select the right installation systems for each project, several factors must first be assessed during the preparation stage.

Dry or wet finishing?
Housing construction uses both dry and wet finishing methods, explains Casper Bontenbal, Marketing Manager at Isolectra. “The choice of pluggable installation materials must, of course, be tailored accordingly. For dry finishing, the well-known IP40 Wieland GST18® system is the best solution. It is flexible, readily available, quick and efficient. However, an IP40 installation system is not suitable when pluggable building components are assembled in very wet conditions. For these situations, Isolectra supplies the IP66/68/69k RST20® system, which guarantees optimal water ingress protection and a high-quality installation in all building conditions. This means installers can also enjoy the benefits of pluggable installations with wet finishing.”

Also suitable for precast concrete construction
Pluggable installations are also possible in precast concrete construction using Wieland RST20®, Bontenbal points out. “This system is so robust and reliable that it is even certified for casting directly into precast concrete walls and floors, without conduit. To bring the installation up to the highest possible standard, our consultants and account managers also provide maximum support. Installers can rely on our extensive electrical engineering expertise and a wide range of building-construction solutions for connecting installations in walls and floors intelligently and efficiently.”
Maintenance-free by design
For pluggable installation connections in inaccessible locations, it is especially important that the connection is maintenance-free. Isolectra and Wieland’s pluggable installation systems are also ideally suited to this. The GST18®, GST15®, RST16® and RST20®, among others, are designed and certified to be entirely maintenance-free.
CPR and Building Regulations
New rules for cables were added to the Building Regulations last year. “Installers should always check which fire and smoke classification their cables must meet,” advises Bontenbal. “In most cases, Dca s2 applies to occupied spaces, Dca s2 or B2ca s2 to protected escape routes, and B2ca s1 to additional protected escape routes. Wieland GST18® cables are available in Dca s1,d2,a1 and B2ca s1,d1,a1, as well as Cca s1,d1,a1 and Eca. All our cables therefore fully comply with the new requirements. This means we can offer a suitable solution for every pluggable installation requirement.”