Building services engineering

‘Reduce magnetic fields in electrical installations’

‘Reduce magnetic fields in electrical installations’

A recurring question about busbar systems concerns electromagnetic compatibility (EMC). More specifically, it concerns the electromagnetic interference (EMI) generated by these systems, in other words, the emission of electromagnetic fields.

“In general, ‘standard’ busbar systems already have relatively very favourable EMC properties,” says Daan Jacobs, Commercial Director at Busbar Systems. “The metal casing of our EAE busbar trunking systems acts as a ‘Faraday cage’, shielding against any radiation that might escape. The Faraday cage principle is widely regarded as the best possible way to neutralise EMC emissions. Other factors that influence the EMC characteristics of a busbar system are the cross-section of the busbar casing and the system load.”

High EMC requirements

For understandable reasons, very high EMC requirements are imposed on the components and equipment used in certain types of projects, such as laboratories, hospitals and data centres, says Jacobs. “This was the case, for example, at the Nano Energie Technik Zentrum (NETZ) project in Duisburg, Germany. To meet these requirements as effectively as possible, EAE Elektrik, in cooperation with its German representative in Duisburg (ABH Stromschienen), developed a special type of busbar several years ago. This busbar system is a modified version of the ‘standard’ EAE KXA busbar system, in which the three phase conductors are positioned side by side in the aluminium busbar casing. The N conductor is the outermost conductor (N-L1-L2-L3).”

Optimum protection

The special EMC busbar has five insulated conductors of equal cross-section, including two separate N conductors, says Jacobs. “The busbar system is arranged as follows: L1-N-L2-N-L3. By further ‘enclosing’ the phase conductors between the N conductors in this way, very effective protection against the non-linear currents generated can be ensured. This reduces magnetic field emissions by a further 90% compared with the standard busbar trunking system.”

Question about this story? Ask your question

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • SubjectBuilding services engineering
Share this article

Advertisement

Follow Installatie & Bouw Nederland

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.