‘A healthy indoor climate goes beyond ventilation alone’
Text Belimo en Lieke BousemaImage Belimo

With the introduction of the Energy Performance of Buildings Directive IV (EPBD IV), improving the sustainability of existing buildings is no longer an optional ambition, but a legal requirement. “The revised European directive focuses on energy performance, monitoring, system efficiency and indoor environmental quality. This shifts the focus from energy consumption alone to the overall performance of buildings,” says Richard Daamen, Managing Director of Belimo and chairman of FHI-Gebouwautomatisering. What does this mean in practical terms for HVAC systems in existing non-residential buildings? And why is ventilation just one of the parameters in the bigger picture?
‘EPBD IV requires a systems approach’
EPBD IV sets stricter requirements for existing buildings. “The key point is that Member States must drive phased improvements to the worst-performing buildings. This has a direct impact on HVAC systems,” says Daamen. “Climate control systems account for as much as 40% of energy use in non-residential buildings. Without optimising these systems, compliance is simply not achievable.” What is new is the emphasis on monitoring, mandatory inspections and system efficiency. “It is no longer just about theoretical energy performance calculations, but demonstrable operational efficiency.”
Ventilation: essential, but not enough
A healthy indoor climate is often reduced to providing sufficient air changes, says Daamen. “However, EPBD IV explicitly links energy performance to Indoor Environmental Quality (IEQ). This means that a future-proof HVAC system must take an integrated approach to CO2 and air quality measurements (demand-controlled ventilation), thermal comfort (temperature stability and minimal overshoot), relative humidity, hydraulic balancing and ΔT optimisation, system efficiency, pump energy, real-time monitoring and data transparency. If you increase ventilation without hydraulic optimisation, energy use rises disproportionately. EPBD IV changes this by putting the balance between health and energy efficiency centre stage.”
Retrofit rather than replacement
Do existing systems need to be completely replaced to comply with EPBD IV? “Not necessarily,” says Daamen. “In many buildings, the basic infrastructure of pipes, air ducts and heat generation equipment is still technically usable. Inefficiency often lies in outdated control valves, non-modulating actuators and a lack of sensor data.” A targeted HVAC upgrade, such as the Belimo RetroFIT+ approach, therefore focuses on:
• Replacing conventional control valves with pressure-independent or intelligent valves;
• Integrating modulating actuators with feedback;
• Implementing flow and energy measurement at system level;
• Improving ΔT in heating and cooling circuits;
• Connecting to BMS for continuous optimisation.
EPBD IV also encourages smart building automation. “Systems above certain capacity thresholds must be equipped with automation and control functions. This often makes retrofitting control technology more urgent than replacing the heat generator.”
ΔT optimisation as a key parameter
One issue that is often overlooked in existing buildings is the so-called low ΔT problem, says Daamen. “Insufficient temperature differences between flow and return lead to reduced heat pump efficiency, lower performance from thermal energy storage systems, higher pump energy use and capacity
problems in distribution networks. Hydraulic imbalance often causes too much water to flow through the system. This may seem like a safe option, but it undermines efficiency. Intelligent control valves can precisely limit and monitor flow rates. This restores thermodynamic efficiency.”
Data as a requirement, not a luxury
EPBD IV places strong emphasis on the digitalisation and transparency of building performance. Continuous monitoring will become the norm. “A healthy indoor climate must be demonstrable,” Daamen summarises. “That means measured data, not just on energy use, but also on comfort parameters. Without data there can be no optimisation, and without optimisation there can be no compliance with the directive. Buildings are thus being transformed from static objects into dynamically controlled energy systems.”
A healthy indoor climate under EPBD IV
The directive explicitly stresses that energy efficiency must not come at the expense of indoor air quality. This means:
• No under-ventilation to improve energy ratings;
• No loss of comfort due to aggressive energy savings;
• An integrated design and management strategy. “The challenge is not to ventilate more or use less energy, but to strike an intelligent balance.”
EPBD IV accelerates HVAC modernisation
EPBD IV makes clear that existing buildings can no longer rely on outdated HVAC systems without monitoring and optimisation. “A healthy indoor climate requires more than ventilation alone,” Daamen emphasises. “It requires thermal stability, hydraulic balance, data-driven control and demonstrable energy efficiency. Targeted HVAC retrofits are therefore no longer an optional improvement, but a strategic step towards legal compliance and future-proof building management.”