AL-KO Luchttechniek is supplying 21 identical air handling units, with a total airflow of 840,000 m3/h.
AL-KO Luchttechniek is supplying 21 identical air handling units, with a total airflow of 840,000 m3/h.

With 64,000 m2 of floor space, Feringa Building will be one of the largest and most impressive university buildings in the Netherlands. The design includes a host of state-of-the-art facilities, and sustainability ambitions are high. AL-KO Luchttechniek’s air handling units are an excellent fit.

AL-KO Luchttechniek specialises in professional air treatment and climate control. Guided by the motto ‘Quality for life’, this Roden-based company has been advising, designing and supplying well-engineered, reliable and efficient air treatment systems for more than 25 years. A bespoke solution was also developed for Feringa Building. “On behalf of De Groot-Lammerink Installatiecombinatie B.V. and the RUG, we are supplying 21 identical air handling units with a total air flow of 840,000 m3/h,” says ing. Anne Rozema, director of AL-KO Luchttechniek. “A cubic metre of air weighs around 1.2 kilos, which means that more than a million kilos of air per hour passes through the filters, plate heat exchangers, heating and cooling coils, air ducts and other system components. Making this possible requires a bit of higher mathematics. In our design, we focused on ways to keep the resistance of the components as low as possible. We then selected the most suitable fans and motors with the highest efficiency, ensuring very favourable life cycle costs.”

Anne Rozema, director of AL-KO Luchttechniek.

Adiabatic cooling

When designing the air handling units, AL-KO Luchttechniek used Arcadis’s specification as its starting point and optimised it wherever possible, Rozema explains. “One key requirement was the integration of adiabatic cooling. For heat recovery, we incorporated a double polypropylene (plastic) plate heat exchanger in our air handling units, offering a very high heat recovery efficiency. In summer, this plate heat exchanger is used as an indirect adiabatic cooler. The extract air removed from Feringa Building is humidified with treated water, lowering its temperature. The cooled extract air is then passed through the plate heat exchanger, where it crosses paths with the fresh outdoor air being drawn in. This technology allows the outdoor air to be cooled efficiently in two stages. In theory, the outdoor air temperature can be reduced by around 8°C, depending on the relative humidity in the building. This offers major benefits during the warm summer months, as it can significantly reduce the need for mechanical cooling capacity.”

High-performance anti-corrosion coating

As laboratory environments can sometimes involve slightly contaminated air, AL-KO Luchttechniek is applying a high-performance anti-corrosion coating to all the air handling units. “This protects both the units and all their components,” says Rozema, who concludes by describing the structural constraints: “All our air handling units have been designed with the structural limitations in mind. The units are delivered to the project just in time and lifted by crane to the top floor, after which the roof is built over them. To protect them from the weather during construction, they are carefully wrapped before delivery.” The final units will be delivered in 2024.      

Question about this story? Ask your question

Who worked on Feringa Building

  1. Building automation modulesWAGOMentioned in Dynamic lighting control for Feringa Building
  2. mechanical and electrical installationsDe Groot-Lammerink Installatiecombinatie B.V.Mentioned in Dynamic lighting control for Feringa Building
  3. complete lighting installationSignum Meet- en RegeltechniekMentioned in Dynamic lighting control for Feringa Building
  4. air handling unitsAL-KO LuchttechniekIn this story
  5. specificationArcadisIn this story
  6. main contractorBallast NedamMentioned in Feringa Building houses a diverse mix of building services
  7. gas distribution systemsDrägerMentioned in Optimal gas distribution for research laboratories
  8. ClientRijksuniversiteit Groningen (RUG)Mentioned in Plug-and-play lighting and power installations for Feringa Building Groningen: Smart & fast
  9. ArchitectEctor HoogstadMentioned in Plug-and-play lighting and power installations for Feringa Building Groningen: Smart & fast

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • ProjectFeringa Building
  • ThemeHealthy indoor air
  • SubjectHVAC
  • CompanyAL-KO Luchttechniek
  • CompanyArcadis
Share this article

Follow Installatie & Bouw Nederland

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.