In the Zijdelwaard district of Uithoorn, a Multifunctional Accommodation (MFA) featuring a sports hall, sports canteen, community room with a professional kitchen and childcare facilities was completed just before the summer building holiday. Sustainability was central to both the design and construction. For example, the new building is largely constructed from Cross Laminated Timber (CLT), a bio-based structure with an attractive appearance that also serves as the wall finish. Wherever possible, materials from the old sports hall have been reused in the new building, making it partly circular. In addition, as many sustainable building services technologies as possible have been used.

Because of the timber building structure and to ensure a high-quality appearance, all air handling units are located inside the building, in the plant room.

MFA Zijdelwaard is a Design & Build project commissioned by the municipality of Uithoorn. Slangen+Koenis Architecten was responsible for the architectural and aesthetic design, while HoffmanDME Techniek handled the technical design. “We are responsible for the design, engineering and installation of all mechanical, plumbing and electrical services,” says project coordinator Gertjan Eshuis. “From water supply to drainage, heating to lighting, and fire alarm systems to measurement and control technology. To bring quality and sustainability up to the highest level, we worked with several partner companies. One good example is Systemair, which supplied four air handling units and a large number of grilles, valves, CAV and VAV dampers. Because of the timber building structure and to ensure a high-quality appearance, we installed all the air handling units inside the building, in the plant room.”

A long-standing, positive relationship

According to Eshuis, choosing Systemair for this project was an obvious decision, thanks to their long-standing, positive relationship. “We have been working together since around 1994, and I have known account manager Derrick Echteld for years too. We understand each other well and often need only a few words to get things moving quickly on projects. The products are also excellent quality. Systemair is a global player that knows what it is doing and what it makes. For example, because the air handling units are manufactured locally in the Netherlands, transport movements and CO2 emissions are kept to a minimum. This is another important driver from a sustainability and environmental perspective.”

Systemair supplied a total of four air handling units, one for each of the MFA’s four user functions.

Configurations

“During the engineering phase, Derrick and I selected and checked the right configuration for each unit,” says Eshuis. “We looked at everything from efficiency and temperature ranges to noise data and controls. Does everything meet the requirements and standards? Where are there opportunities to optimise? Which fans offer the highest efficiency? And what impact will that have on energy consumption?” He says the delivery schedule for the units was tight, as they had to be hoisted into place before the roof was closed. “Fortunately, all the units were ordered well in advance, so there were no delivery issues. We positioned and assembled them together. We also carried out the commissioning together just before handover.”

The new building is largely constructed from Cross Laminated Timber, a bio-based structure with an attractive appearance that also serves as the wall finish.

The building’s lungs

Systemair supplied a total of four air handling units, one for each of the MFA’s four user functions. “The air handling units are the building’s lungs, ensuring an adequate supply of fresh air in all occupied areas,” says Eshuis. “They also provide heating and cooling. In consultation with Systemair, we chose the new Geniox air handling units, which meet high Eurovent classes and guarantee an efficiency of 85%.”

Units with capacities of 22,000, 6,500, 4,500 and 5,000 m3/h were supplied to meet the space requirements. “Ventilation air is supplied through sinus nozzle grilles. These grilles allow the airflow to be controlled very effectively, so occupants are not troubled by draughts or cold spots.” Constant Air Volume (CAV) dampers have been installed in most areas, he says. “Because occupancy fluctuates significantly in part of the building, Variable Air Volume (VAV) dampers were chosen there. This allows these spaces to be climate-controlled according to demand and temperature, avoiding wasted energy. Sustainability and comfort go hand in hand.”      

A business enquiry for Systemair? Get in touch

Who worked on it

MFA Zijdelwaard in Uithoorn

  1. air handling unitsSystemair
  2. architectSlangen+Koenis Architecten
  3. technical detailingHoffmanDME Techniek

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • ProjectMFA Zijdelwaard
  • ThemeSustainable refurbishment of existing buildings
  • SubjectProjects
  • CompanySystemair
  • CompanySlangen+Koenis Architecten
  • CompanyHoffmanDME Techniek
Share this article

Follow Installatie & Bouw Nederland

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.