Projects

Upfield SU Nederland BV, Rotterdam | Dynamic, food-safe lighting for margarine factory in Rotterdam

Upfield SU Nederland BV, Rotterdam | Dynamic, food-safe lighting for margarine factory in Rotterdam

Upfield SU Nederland BV’s 125-year-old margarine factory on Nassaukade in Rotterdam…

Upfield SU Nederland BV’s 125-year-old margarine factory (formerly Unilever BCS Europe B.V.) on Nassaukade in Rotterdam has recently been expanded with the Upfield Research & Development Pilot Plant. All of Upfield’s global Research & Development activities have been brought together in this new building. D&S Process Solutions carried out the construction and delivered it on a turnkey basis, also providing the building services. Including the lighting.

“D&S Process Solutions was looking for food-safe luminaires that could also be controlled dynamically. Our Luci Series Industry LED luminaires are ideally suited to this,” says Jeroen de Jonge, Sales Director at Bever Innovations, Industrial division. “For the Pilot Plant, we supplied Luci luminaires installed in the ceilings using special recessed frames, which we normally use in the petrol retail market. All the luminaires have been sealed with a special food-safe sealant, creating a completely flush ceiling. The recessed luminaires are also impact-resistant, splinter-free and made from an easy-to-clean material, making them fully compliant with HACCP guidelines. As the ceiling can be walked on, Upfield SU Nederland’s service technicians can easily access and clean the luminaires.”

When employees enter the space, the lighting automatically switches on to a predetermined level, taking into account the amount of daylight entering the room, the room temperature and the applicable occupational health and safety standards.

Bright, energy-efficient and safe

“As the Pilot Plant in Rotterdam is a testing facility, bright light and even illumination were essential,” says Perry Snoeij, Automation & Control Manager at Upfield SU Nederland BV. “The new building also lets in a great deal of daylight, so daylight controls were required.” De Jonge adds: “The specified lighting level was at least 300 lux. We ultimately supplied luminaires providing more than 500 lux. The daylight sensor is activated in the luminaires. All the lighting is also controlled dynamically. When employees enter the space, the lighting automatically switches on to a predetermined level, taking into account the amount of daylight entering the room, the room temperature and the applicable occupational health and safety standards. The lighting then dims automatically again. Some lights have been designated as emergency lighting and are always on at a minimum illumination level. This means optimal energy efficiency and safety go hand in hand.”

The new building was brought into use in mid-March. “The feedback from our employees has been very positive,” says Snoeij. “The light is considered very comfortable, and the motion and daylight controls mean no energy is wasted anywhere. On sunny days, the luminaires operate at just 10 to 11 per cent of their capacity.”

Compressed air shut-off valves.

Test installation

Following the new-build project, Bever Innovations has also been commissioned to install several test setups in the existing building on Nassaukade, where a number of lighting challenges need to be addressed. “The existing fluorescent lighting has reached the end of its technical service life,” says De Jonge. “Upfield SU Nederland BV also has insufficient light in certain areas. Luminaires regularly fail because of the heat generated during margarine production. In addition, plastic parts dry out over time. We have worked closely with Upfield SU Nederland to develop an alternative lighting solution that also allows for dynamic control. Over the coming weeks, we will be lighting several platforms using our new CubiQ luminaire. There is also a request in progress to light an entire margarine production line.”

New product: the CubiQ luminaire

The CubiQ luminaire is ideal for spaces up to 4 to 5 metres high and as an addition to existing task lighting, says De Jonge. “CubiQ can easily be adjusted from 0 to 9,000 lumens. The luminaire operates at just 48 volts and is centrally powered. Multiple units can be controlled from a single driver. This is not only useful in hard-to-reach places, but also in locations where temperatures rise significantly. The driver can be installed elsewhere, which considerably extends the products’ service life.”   

Een zakelijke vraag aan Bever Innovations Industrial? Get in touch

Who worked on it

Upfield Research & Development Pilot Plant in Rotterdam, new build

  1. Luci-armaturenBever
  2. building services engineeringD&S Process Solutions

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • ProjectUpfield Research & Development Pilot Plant
  • ThemeBuilding electrical systems
  • SubjectProjects
  • CompanyBever Innovations Industrial
  • CompanyD&S Process Solutions
Share this article

Follow Installatie & Bouw Nederland

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.