Antoni van Leeuwenhoek air handling system successfully upgraded
Text Lieke BousemaImage Systemair

In 2018, Antoni van Leeuwenhoek, the Amsterdam hospital and research institute specialising in cancer, upgraded and made its central heating and cooling generation more sustainable as part of its planned transition from high-temperature to low-temperature generation. Last year, Systemair upgraded the air handling system, refurbishing and improving the energy efficiency of the existing air handling units. ULC Installatietechniek also commissioned Systemair to replace two existing units with new HHFlex units, distinguished by their project-specific configuration, high performance and excellent energy efficiency.

As many as 35 years ago, manufacturer Holland Heating, now Systemair, was one of the first companies on the Dutch market to start improving the energy efficiency of air handling units. “In the 1970s and 1980s, we supplied Holland Heating units to all the university hospitals in the Netherlands,” says Sjef Verboven, account manager at Systemair. “Ten to fifteen years later, the first requests for modifications and energy-efficiency upgrades came in, as they have recently at Antoni van Leeuwenhoek. Although the casings of the air handling units were still in good condition, the technology had reached the end of its service life.”
Refurbishment and energy-efficiency upgrades
“The Dutch DUMAVA subsidy scheme enables organisations such as healthcare institutions to improve the energy efficiency of their public buildings,” says Verboven. “Antoni van Leeuwenhoek has also made use of the scheme. We replaced the old belt-driven fans with V-belts with direct-drive fans, significantly improving the performance of the existing air handling units. We also disconnected the old steam humidification systems and/or replaced them with energy-efficient adiabatic humidification.”

New HHFlex units
Two air handling units were not suitable for refurbishment and energy-efficiency upgrades. “At the request of ULC Installatietechniek, we replaced these existing units with new HHFlex units incorporating the latest technology,” says Verboven. “From fans to thermal wheels and adiabatic humidification. Our HHFlex units are distinguished by their modular design, an A energy rating, heat recovery efficiency of more than 80 per cent and the use of fans fitted with IE5 permanent magnet motors.”
As the new air handling units had to be installed indoors, Systemair began by surveying the old units and the site. “Based on the specifications of the existing units and the new requirements, we worked with Jeroen Schevers of ULC Installatietechniek to configure the right air handling units for Antoni van Leeuwenhoek,” says Verboven. “Logistics were also given particular attention.”

Manageable sections
Both air handling units have a maximum airflow rate of 25,000 m3/h and measure 9 metres long, 3 metres wide and 3 metres high. “As Antoni van Leeuwenhoek is an existing hospital with a closed roof and façades, we could not simply hoist these units inside,” says Verboven. “Instead, they were divided into manageable sections and assembled on site. The heat recovery section with the thermal wheel was the only part assembled in situ, as it was too large to bring inside in one piece.”
The air handling unit was installed in building section D2 in November 2025. The unit for building section D1 followed in January 2026, after which ULC Installatietechniek was responsible for connecting the water pipework, balancing and commissioning.